Conductor

Bunched Conductors

Insulation

Laid Up Cores

Foil Screen

Atc Braid

Outer Sheath



Conductor

Bunched Conductors

Insulation

Laid Up Cores

Foil Screen

Atc Braid

Outer Sheath
These cables are used as data and control cable in machinery. The high level of screening ensures a high degree of interference protection.
Such cables can also be used for outdoor applications for the permitted temperature range.
Standard : In acc to HD 21.13 S1 resp. VDE 0281-13 and HD 22.10 S1
Temperature Range : Flexing -5°C to +70°C. Fixed installation -30°C to +70°C
Nominal Voltage : U / U 300 / 500 V O
Insulation Resistance : Min. 20 GΩ x cm
Minimum Bending Radius : Flexing 20 x cable ø. Fixed installation 6 x cable ø
Test Voltage : Core/core: 4000V. Core/screen: 2000V
Bare copper, fine wire conductors, bunch stranded EN 60228 Cl. 5.
Core insulation of PVC TI2, EN 50363-3.
Black core with continuous white numbering to DIN VDE 0293.
Green/yellow earth core in outer layer (3 cores and above).
Cores stranded in layers with optimal lay-length.
PETP tape.
Tinned copper, braided screen, approx 85% coverage.
Special polyurethane outer sheath (PUR).
Sheath colour : Grey (RAL 7001).
Extensively oil resistant.
Abrasion and notch resistant.
Low adhesive surface.
Resistant to hydrolysis and microbes.
UV resistant to ASTM G 154.
The screening density assures disturbance-free transmission of all signals and impulses.
To optimize the EMC features we recommend a large round contact of copper braiding on both ends