Conductor

Bunched Conductor

Insulation

Laid Up Cores

Inner Sheath

Atc Braid

Outer Sheath



Conductor

Bunched Conductor

Insulation

Laid Up Cores

Inner Sheath

Atc Braid

Outer Sheath
These are halogen free cables used as data and control cable in machinery. The high level of screening ensures a high degree of interference protection.
The special inner sheath aids to the increase in flexibility for robust application. Such cables can also be used for outdoor applications for the permitted temperature range.
Standard : Adapted to EN 50525-2-51
Nominal Voltage : U / U 300 / 500V O
Insulation Resistance : Min. 20 GΩ x cm
Temperature Range : Flexing -40°C to +90°C. Fixed installation -50°C to +90°C
Minimum Bending Radius : Flexing 15 x cable ø. Fixed installation 6 x cable ø
Test Voltage : 3000V
Bare copper, fine wire conductors, bunch stranded EN 60228 Cl. 5.
Core insulation of TPE.
Black core with continuous white numbering to DIN VDE 0293.
Green/yellow earth core in outer layer (3 cores and above).
Cores stranded in layers with optimal lay-length.
TPE inner sheathed.
Tinned copper braided screen.
Special polyurethane outer sheath (PUR).
Sheath colour : Grey (RAL 7001).
Extensively oil resistant.
Abrasion and notch resistant.
Low adhesive surface.
Resistant to hydrolysis and microbes.
Halogen free and flame retardant to EN 60332-1-2.
UV resistant to ASTM G 154.
To optimise the EMC features we recommend a large round contact of the copper braiding on both ends.
Note :
* G = With green/yellow earth core
X = Without green/yellow earth core (OZ)